Glitch Tamer Six - P31066
UL Listing 100902
Glitch Tamer®
Six The Glitch Tamer®is a six-pair device
designed to control AC voltage that is causing lost productivity and faulty operation of
customer key systems and PBXs. Installed on the customer side of the network interface,
the economical Glitch Tamer controls low level voltages (less than 50 Volts AC) that are
causing problems.
Glitch Tamer®
Igniter When a Glitch Tamer® Six is installed,
one of the pairs going through the Glitch Tamer®
must be grounded at the central office and at the station to provide a primary winding or
"exciting" pair. The Igniter allows the use of a working pair to "turn
on" or provide the necessary exciting current path to make the Glitch Tamer® function effectively. The result is that a spare pair
is no longer required to be grounded at both ends of a neutralized cable route.
The igniter is a drainage reactor,
specifically designed for either 50 or 60 Hz. It is easily bridged across one working
circuit, thus providing a low impedance path-to-ground for longitudinal power line-induced
interfering current flow. One igniter is normally required for each Glitch Tamer® Six installation.

Glitch Tamer Igniter - P31069
UL Listing 100902
SNC
Manufacturing Co., Inc.
101 West Waukau
Avenue
Oshkosh, WI 54902-7299